Otherwise heat from your wood stove will flow out through the uninsulated opening.
Through roof wood burner flue.
To start attach the first flue section to the vent collar on the fireplace.
Minimum clearance from combustible material.
For air cooled chimneys attach the inner section first then the outer section.
The chimney pipe must protrude through the roof a minimum of 2 feet and it must be at least 10 feet away from the roof line.
450 mm 18 in.
It will have to safely protrude through the attic and roof in order to ventilate your home and allow your stove to work properly.
Stovesonline can design plan specify supply and support fitting i wide range of lead nu lead alu based or epdm flashing to enable leak proof and watertight joins between your flue system chimney and roof.
Duraplus chimney is a triple wall all fuel chimney for use with wood stoves fireplaces furnaces boilers stoves ranges water heaters or other appliances fueled by wood oil coal or gas product weight.
If you re installing a wood burning stove in your home one of the final stages is the chimney.
The minimum clearance may be reduced by 50 percent to 225 mm 9 in if suitable shielding is installed either on the pipe or on the combustible surface.
A flue pipe must never pass through a combustible floor or ceiling or through an attic roof space closet or concealed space.
In contrast solid pack chimneys typically feature an anchor plate.
If your roof is metal this can be a little bit trickier.
Manufacturer part number 6dp kbsc.
All chimneys must extend 3 feet above the roof surface and 2 feet higher than any part of the building within 10 feet.
Next using a 5 16 nut driver attach the chimney rain cap to the chimney pipe.
How to install a wood stove chimney through a wall or roof non chimney installs 1 start your system with a length of single wall vitreous enamel stove pipe in the same diameter as the outlet on the.
2 connect a single to twin wall adapter to convert from this single wall pipe to insulated.